If monitoring is selected to “Enable”, an
operator can designate monitoring time by
minute unit. (Settable value: 0-60)
(9) Fault Handling
Display/set setting information related to fault.
Property Description
Default
setting
Degraded Partition Boot Policy
Set the reboot policy for degraded partition.
Boot
reboot the partition that the failure unit
belongs to.
NotBoot
does not reboot the partition that the failure
unit belongs to.
Boot
Failing Unit Removal
Enable or disable automatically removing of the
failure unit.
Disable failing units
Disable that the failure unit will be removed
automatically from the partition.
Enable failing units
Enable that the failure unit will be removed
automatically from the partition.
Disable failing
units
Partition Boot Retry Times
Specify the retry count of partition boot at
partition boot failure.
Retry Times
A user can designate server boot retry times.
(Settable value: 0-9)
5(times)