EasyManua.ls Logo

R&S FSW Series - Page 857

R&S FSW Series
1450 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Commands
R&S
®
FSW
857User Manual 1173.9411.02 ─ 43
Usage: Query only
CALCulate<n>:LIMit<li>:ACPower:ALTernate<ch>[:RELative]:STATe
This command turns the relative limit check for the alternate channels on and off.
You have to activate the general ACLR limit check before using this command with
CALCulate<n>:LIMit<li>:ACPower[:STATe].
Suffix:
<n>
.
irrelevant
<li> irrelevant
<ch> 1..n
Alternate channel number
Parameters:
<State> ON | OFF | 1 | 0
Relative limit check for lower alternate channel
*RST: 0
<State>
Manual operation: See "Limit Check" on page 176
See "Limit Checking" on page 188
CALCulate<n>:LIMit<li>:ACPower[:STATe] <State>
This command turns the limit check for ACLR measurements on and off.
In addition, limits must be defined and activated individually for each channel (see
CALCulate<n>:LIMit<li>:ACPower:ACHannel[:RELative]:STATe,
CALCulate<n>:LIMit<li>:ACPower:ALTernate<ch>[:RELative]:STATe,
CALCulate<n>:LIMit<li>:ACPower:GAP<gap>[:AUTO]:ABSolute:STATe,
CALCulate<n>:LIMit<li>:ACPower:GAP<gap>[:AUTO]:ACLR[:RELative]:
STATe and CALCulate<n>:LIMit<li>:ACPower:GAP<gap>[:AUTO][:
CACLr][:RELative]:STATe).
Suffix:
<n>
.
irrelevant
<li> irrelevant
Parameters:
<State> ON | OFF | 1 | 0
*RST: 0
Manual operation: See "Limit Check" on page 176
See "Limit Checking" on page 182
See "Limit Checking" on page 188
Configuring and Performing Measurements