Remote Commands
R&S
®
FSW
906User Manual 1173.9411.02 ─ 43
CONFigure:GENerator:NPRatio:NOTCh<notch>:CLOCk?..................................................911
CONFigure:GENerator:NPRatio:NOTCh<notch>:COUNt:CSTate?.......................................911
CONFigure:GENerator:NPRatio:POWer:LEVel:CSTate?.................................................... 912
CONFigure:GENerator:NPRatio:POWer:LEVel:OFFSet:CSTate?........................................ 912
CONFigure:GENerator:NPRatio:RFOutput:STATe:CSTate?................................................ 913
CONFigure:GENerator:NPRatio:SETTings:NOTCh:UPDate............................................... 913
CONFigure:GENerator:NPRatio:SETTings:UPDate........................................................... 913
CONFigure:GENerator:NPRatio:STATe:CSTate?...............................................................913
CONFigure:GENerator:NPRatio[:STATe]...........................................................................914
CONFigure:GENerator:POWer:LEVel...............................................................................914
CONFigure:GENerator:POWer:LEVel:OFFSet.................................................................. 914
CONFigure:GENerator:RFOutput[:STATe].........................................................................914
CONFigure:GENerator:TARGet:PATH:BB?.......................................................................915
CONFigure:GENerator:TARGet:PATH:RF.........................................................................915
CONFigure:SETTings:NPRatio........................................................................................915
CONFigure:SETTings:NPRatio:NOTCh............................................................................ 915
CONFigure:GENerator:EXTernal:ROSCillator <ReferenceType>
Selects the source of the generator reference frequency.
Parameters:
<ReferenceType> EXTernal | INTernal
EXTernal
An external reference is provided via the EXT connectors on the
generator, for example by the R&S FSW.
INTernal
The internal reference is that of the signal generator itself.
Manual operation: See "Reference Frequency" on page 230
CONFigure:GENerator:FREQuency:CENTer <Frequency>
Defines the frequency of the signal provided by the signal generator.
Parameters:
<Frequency> Default unit: HZ
Example:
CONF:GEN:FREQ:CENT 1GHZ
Manual operation: See "Frequency" on page 230
See "f
Gen
" on page 232
CONFigure:GENerator:NPRatio:BB:ARBitrary:WAVeform:SELect?
Queries the ARB waveform file currently used by the signal generator.
Return values:
<ArbWaveform>
Example:
CONF:GEN:NPR:BB:ARB:WAV:SEL?
Usage: Query only