RL78/G10 CHAPTER 6 TIMER ARRAY UNIT
R01UH0384EJ0311 Rev. 3.11 137
Dec 22, 2016
Channel 1: Slave
Channel 0: Maste
r
Channel group 1
(Simultaneous channel operation
function)
* The operating clock of channel group 1 may
be different from that of channel group 2.
Channel
:Master
CK00
CK00
TAU0
Channel group 2
(Simultaneous channel operation
function)
Channel 2: Slave
Channel 1: independent
channel operation
CK01
* A channel that operates independent
channel operation function may be between
a master and a slave of channel group 1.
Furthermore, the operating clock may be set
separately.
Channel 3: Slave
Channel 2: Maste
r
CK01
TAU0
Channel group 1
(Simultaneous channel operation
function)
Example

Table of Contents