Error Name/Error Condition/Major Cause/Solution
RESUME:PCI-Express bus ROOT_DL status error
RESUME:PCI-Express bus DETUP status error
"0x53554D45" -> Link up error
Also, error code "0x5245" and detail code ""0x53554D45" -> Link up error"
appears on operation panel.
• Turn the main power OFF/ON.
• Replace the controller board (PCB15) or the BiCU (PCB16).
L2 status register between Engine ASIC and Veena has not reached the
target value within 1 sec.
Engine ASIC during the operation was rebooted or shifted to energy saving
mode.
Machine reboots when SC23x, SC30x occurs.
If Engine ASIC is working when rebooting (or shifting to the energy saving
mode), L2 status value is not on target.
The following message appears on the console.
SUSPEND:PCI-Express L2 Status Check Error
Also, error code "0x5355" and detail code ""0x5350454E44" -> L2 status
time out" appears on operation panel.
• Turn the main power OFF/ON.
• Replace the controller board (PCB15) or the BiCU (PCB16).
Received file system data was broken even if the initialization succeeds and
there was no error reply from the HDD.
Power supply disconnection during data writing to the HDD.
Replace the HDD.
This SC may occur when turning on the machine for the first time with a new
HDD. In this case, turn the main power OFF/ON.
If the SCS process is ended for some reason
If an unexpected error occurs at SCS processing end, gwint processing also
halts (this result is judged a kernel stop error, by gwinit specification)
"0x69742064" -> "init died"
Turn the main power OFF/ON.
Occurs when too much RAM is used during system processing