1Getting Started
38 InfiniiVision 7000B Series Oscilloscopes User’s Guide
5. AutoProbe Interface When you connect a probe to the oscilloscope, the
AutoProbe Interface attempts to determine the type of probe and set its
parameters in the Probe Menu accordingly. See “AutoProbe Interface” on
page 52.
6. [Label] Key Press this key to access the Label Menu, which lets you
enter labels to identify each trace on the oscilloscope display. See “Using
Labels” on page 89.
7. Vertical Position Control Use this knob to change the channel’s vertical
position on the display. There is one Vertical Position control for each
channel. See “Using the Vertical Controls” on page 77.
8. Vertical Sensitivity There is one knob marked for each channel. Use
these knobs to change the vertical sensitivity (gain) of each channel. See
“Using the Vertical Controls” on page 77.
9. Channel On/Off Key Use this key to switch the channel on or off, or to
access the channel’s menu in the softkeys. There is one Channel On/Off
key for each channel. See “Using the Vertical Controls” on page 77.
10. Tools Controls Press this key to access the Utility Menu, which lets you
configure the oscilloscope’s I/O settings, use the file explorer, set
preferences, access the service menu, and choose other options.
11. File Keys Press the [Save/Recall] key to save or recall a waveform or
setup. The [Print] key opens the Print Configuration Menu so you can print
the displayed waveforms. See “Saving and Recalling Data” on page 206
and “Printing Screens” on page 220.
12. Math Controls The [Math] key provides access to add, subtract,
multiply, differentiate, integrate, FFT (Fast Fourier Transform) and square
root functions. See “Measurements and Math Functions” on page 153.
13. Digital Channel Controls These controls switch the digital channels on
and off, and can be used to select a digital channel for repositioning on
the display.
Press the [Digital] key to turn on the digital channels (the [Digital] key will
illuminate as well as the arrow to the left).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 7000B Series and is the answer not in the manual?

Agilent Technologies 7000B Series Specifications

General IconGeneral
BrandAgilent Technologies
Model7000B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals