Level 2 safety reset P0608
Error cause
•
As the level 2 safety system (comparison between requested torque and calculated torque)
has detected a fault, the control unit has reset engine (C gravity). The instrument panel does
not indicate the presence of this error even in the ATT status.
Troubleshooting
•
Continue fault search for the other errors detected
Safety Engine Stop P0609
Error cause
•
Since the safety system has detected a serious fault, the control unit has shut off the engine
Troubleshooting
•
Continue fault search for the other errors detected.
Saved data file (for safety) P0611
•
Filled
Error cause
•
This indication appears only if the Level 2 safety has reset the engine (C gravity). The in-
strument panel does not indicate the presence of this error even in the ATT status
Troubleshooting
•
Continue fault search for the other errors detected.
DIAGNOSIS INSTRUMENT: ADJUSTABLE PARAMETERS
Cylinders pressure balance
•
It allows balancing the cylinders 1-3 and then the cylinders 2-4 by the by-pass screws
Control unit EEPROM zero setting
CAUTION
DELETING ALL THE SAVED DATA WHEN THE VEHICLE IS BEING MANUFACTURED (INCLUD-
ING THE SELF-ADJUSTABLE PARAMETERS), THEN YOU MUST SELECT: THROTTLE GRIP
SELF-ACQUISITION AND CHECK THE TWO "FRONT THROTTLE AUTOMATIC SELF-ACQUISI-
TION" AND "REAR THROTTLE AUTOMATIC SELF-ACQUISITION" STATUSES ARE "PER-
FORMED".
See also
Cylinders synchronisation
Saved data file download
Error cause
•
The BUFRSVXX.BIN file is saved in the Axone memory card or in your hard disk PC, if you
are using Piaggio Group Diagnostic Software combined to Navigator or Axone: data re-
RSV4 R Electrical system
ELE SYS - 147