Version 7.2 1009 Mediant 800B Gateway & E-SBC
User's Manual 64. Syslog and Debug Recording
Parameter Description
Filter Type
filter-type
[LoggingFilters_FilterType]
Defines the filter type criteria.
ï‚§ [1] Any (default)
ï‚§ [2] Trunk ID = Filters log by Trunk ID. Note: Applicable only to
the Gateway application.
ï‚§ [3] Trunk Group ID = Filters log by Trunk Group ID. To configure
Trunk Groups, see Configuring Trunk Groups on page 517.
Note: Applicable only to the Gateway application.
ï‚§ [4] Trunk & B-channel = Filters log by Trunk and B-channel.
Note: Applicable only to the Gateway application.
ï‚§ [5] FXS or FXO = Filters log by FXS and/or FXO port.
ï‚§ [6] Tel-to-IP = Filters log by Tel-to-IP routing rule. To configure
Tel-to-IP routing rules, see Configuring Tel-to-IP Routing Rules
on page 525. Note: Applicable only to the Gateway application.
ï‚§ [7] IP-to-Tel = Filters log by IP-to-Tel routing rule. To configure
IP-to-Tel routing rules, see Configuring IP-to-Tel Routing Rules
on page 534. Note: Applicable only to the Gateway application.
ï‚§ [8] IP Group = Filters log by IP Group. To configure IP Groups,
see 'Configuring IP Groups' on page 365.
ï‚§ [9] SRD = Filters log by SRD. To configure SRDs, see
Configuring SRDs on page 347.
ï‚§ [10] Classification = Filters log by Classification rule. To
configure Classification rules, see Configuring Classification
Rules on page 701. Note: Applicable only to the SBC
application.
ï‚§ [11] IP-to-IP Routing = Filters log by IP-to-IP routing rule. To
configure IP-to-IP routing rules, see Configuring SBC IP-to-IP
Routing Rules on page 709. Note: Applicable only to the SBC
application.
ï‚§ [12] User = Filters log by user. The user is defined by username
or username@hostname in the Request-URI of the SIP
Request-Line. For example, "2222@10.33.45.201", which
represents the following INVITE:
INVITE sip:2222@10.33.45.201;user=phone
SIP/2.0
ï‚§ [13] IP Trace = Filters log by an IP network trace, Wireshark-like
expression. For more information, see 'Filtering IP Network
Traces' on page 1011.
ï‚§
[14] SIP Interface = Filters log by SIP Interface. To configure SIP
Interfaces, see Configuring SIP Interfaces on page 357.
Value
value
[LoggingFilters_Value]
Defines the value for the filtering type configured in the 'Filter Type'
parameter.
The value can include the following:
ï‚§ A single value.
ï‚§ A range, using a hyphen "-" between the two values. For
example, to specify IP Groups 1, 2 and 3, configure the
parameter to "1-3" (without apostrophes).
ï‚§ Multiple, non-contiguous values, using commas "," between
each value. For example, to specify IP Groups 1, 3 and 9,
configure the parameter to "1,3,9" (without apostrophes).
ï‚§ Trunks/FXO/FXS pertaining to a module, using the syntax
module number/port or port, for example:

Table of Contents

Other manuals for AudioCodes Mediant 800B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800B and is the answer not in the manual?

AudioCodes Mediant 800B Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 800B
CategoryGateway
LanguageEnglish

Related product manuals