User's Manual 1092 Document #: LTRT-10632
Mediant 800B Gateway & E-SBC
Parameter Description
[PacketSmartAgentMode]
Note: For the parameter to take effect, a device reset is required.
PacketSmart Server IP
Address
configure system >
packetsmart server
address
[PacketSmartIpAddress]
Defines the IP address of the PacketSmart server with which the
PacketSmart agent communicates.
The default is 0.0.0.0.
PacketSmart Server Port
configure system >
packetsmart server
port
[PacketSmartIpAddressPort]
Defines the TCP port of the PacketSmart server to which the
PacketSmart agent connects.
The default is 80.
Monitoring Interface
configure system >
packetsmart monitor
voip interface-if
[PacketSmartMonitorInterface]
Assigns an IP network interface (configured in the IP Interfaces
table) that handles the voice traffic.
Note: For the parameter to take effect, a device reset is required.
Network Interface
configure system >
packetsmart network
voip interface-if
[PacketSmartNetworkInterface
]
Assigns an IP network interface (configured in the IP Interfaces
table) for communicating with the PacketSmart server. This is
typically the OAMP interface.
Note: For the parameter to take effect, a device reset is required.
72.4 HA Parameters
The High Availability (HA) parameters are described in the table below.
Table 72-23: HA Parameters
Parameter Description
HA Device Name
configure network > high-
availability > unit-id-name
[HAUnitIdName]
Defines a name for the active device, which is displayed on the Home
page to indicate the active device.
The valid value is a string of up to 128 characters. The default value is
"Device 1".
Redundant HA Device
Name
configure network > high-
availability > redundant-
unit-id-name
Defines a name for the redundant device, which is displayed on the
Home page to indicate the redundant device.
The valid value is a string of up to 128 characters. The default value is
"Device 2".
HA Remote Address
configure network > high-
availability > remote-
address
[HARemoteAddress]
Defines the Maintenance interface address of the redundant device in
the HA system.
By default, no value is defined.
Note: For the parameter to take effect, a device reset is required.
Preempt Mode Enables HA switchover based on HA priority.

Table of Contents

Other manuals for AudioCodes Mediant 800B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800B and is the answer not in the manual?

AudioCodes Mediant 800B Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 800B
CategoryGateway
LanguageEnglish

Related product manuals