User's Manual 1226 Document #: LTRT-10632
Mediant 800B Gateway & E-SBC
Parameter Description
must be less than
CasStateMachineDTMFMaxOnDetectionTime.
The value must be a positive value. The default is -1.
MAX Incoming Address Digits
[CASStateMachineMaxNumOfIncomingAdd
ressDigits]
Defines the limitation for the maximum address digits
that need to be collected. After reaching this number of
digits, the collection of address digits is stopped.
The value must be an integer. The default is -1.
MAX Incoming ANI Digits
[CASStateMachineMaxNumOfIncomingANI
Digits]
Defines the limitation for the maximum ANI digits that
need to be collected. After reaching this number of
digits, the collection of ANI digits is stopped.
The value must be an integer. The default is -1.
Collect ANI
[CASStateMachineCollectANI]
In some cases, when the state machine handles the
ANI collection (not related to MFCR2), you can enable
the state machine to collect ANI or discard ANI.
[0] No = Don't collect ANI.
[1] Yes = Collect ANI.
[-1] Default = Default value.
Digit Signaling System
[CASStateMachineDigitSignalingSystem]
Defines which Signaling System to use in both
directions (detection\generation).
[0] DTMF = DTMF signaling.
[1] MF = (Default) MF signaling.
[-1] Default = Default value.
72.11.6.4 ISDN Parameters
The ISDN parameters are described in the table below.
Table 72-61: ISDN Parameters
Parameter Description
ISDN Termination Side
configure voip > interface e1-t1|bri >
isdn-termination-side
[TerminationSide]
Determines the ISDN termination side.
[0] User side = (Default) ISDN User Termination Equipment
(TE) side.
[1] Network side = ISDN Network Termination (NT) side.
Note: Select 'User side' when the PSTN or PBX side is
configured as 'Network side' and vice versa. If you don't know
the device's ISDN termination side, choose 'User side'. If the
D-channel alarm is indicated, choose 'Network Side'.
The BRI module supports the ITU-T I.430 standard, which
defines the ISDN-BRI layer 1 specification. The BRI and PRI
ports are configured similarly, using the parameter. When an
NT port is active, it drives a 38-V line and sends an INFO1
signal (as defined in ITU-T I.430 Table 4) on the data line to
synchronize to a TE port that might be connected to it. To stop
the voltage and the INFO1 signal on the line, stop the trunk
using the Stop Trunk button.
[TerminationSide_x] Same as the description for parameter TerminationSide, but
for a specific trunk ID (where x denotes the Trunk ID and 0 is
the first Trunk).

Table of Contents