User's Manual  864  Document #: LTRT-10632 
 
  Mediant 800B Gateway & E-SBC 
•  Non-Hitless Upgrade: Installs the License Key simultaneously on both devices 
where both undergo a reset and therefore, current calls are terminated. When 
you click the button, the process starts and the following progress message box 
appears: 
Figure  48-12: Reset in Progress for License Key 
 
When installation completes, the following message box appears: 
Figure  48-13: Reset and Save-to-Flash Success Message 
 
6.  Clock Close to close the message box; you are logged out of the Web interface and 
prompted to log in again. The features and capabilities displayed on the License Key 
page now reflect the newly installed License Key. 
 
 
 
 
 
 
48.2.2  Installing License Key through CLI 
To install the License Key through CLI, use the following commands: 
  To install the License Key:  
(config-system)# feature-key <"string enclosed in double 
quotation marks"> 
  To view the License Key:  
show system feature-key 
48.2.3  Verifying Installed License Key 
Once you have finished installing the new License Key, verify that it has been installed: 
  On the License Key page, check that the listed features and capabilities of the newly 
installed License Key match those that you ordered.  
  Access the Syslog server and check that the following message appears:  
"S/N<serial number> Key Was Updated. The Board Needs to be Reloaded with 
ini file\n" 
If the Syslog server indicates that the License Key was unsuccessfully loaded (i.e., the 
"SN_" line is blank), do the following preliminary troubleshooting procedures: 
1.  Open the License Key file and check that the "S/N" line appears. If it does not 
appear, contact AudioCodes. 
2.  Verify that you have loaded the correct file. Open the file and ensure that the first 
line displays "[LicenseKeys]". 
3.  Verify that the content of the file has not been altered.