User's Manual  156  Document #: LTRT-10632 
 
  Mediant 800B Gateway & E-SBC 
Name' field in the Static Routes table to the same value as configured in the 'Ethernet 
Device' field in the IP Interfaces table. 
  The static route's Gateway address in the Static Routes table is in the same subnet as 
the IP address of the IP network interface in the IP Interfaces table. 
Figure  12-4: Example of using a Static Route 
 
 
12.6.2  Troubleshooting the Static Routes Table 
When adding a new static route to the Static Routes table, the added rule passes a 
validation test. If errors are found, the static route is rejected and not added to the table. 
Failed static route validations may result in limited connectivity (or no connectivity) to the 
destinations specified in the incorrect static route. For any error found in the Static Routes 
table or failure to configure a static route, the device sends a notification message to the 
Syslog server reporting the problem. 
Common static routing configuration errors may include the following: 
  The IP address specified in the 'Gateway' field is unreachable from the IP network 
interface associated with the static route. 
  The same destination has been configured in two different static routing rules. 
  More than 30 static routes have been configured.