Version 7.2 1045 Mediant 800B Gateway & E-SBC
User's Manual 69. Testing SIP Signaling Calls
to answer and end calls many times for batch testing. The calls are initiated from
Device A, where Device B serves as the remote answering endpoint.
Figure 69-7: Batch Test Call Example
Test Call Rules table configuration at Device A:
Endpoint URI: "101"
Called URI: "201"
Route By: Dest Address
Destination Address: "10.13.4.12"
SIP Interface: SIPInterface_0
Call Party: Caller
Maximum Channels for Session: "3" (configures three endpoints - "101",
"102" and "103)
Call Duration: "5" (seconds)
Calls per Sec: "1"
Test Mode: Continuous
Test Duration: "3" (minutes)
Schedule Interval: "180" (minutes)
Test Call Rules table configuration at Device B:
Endpoint URI: "201"
Maximum Channels for Session: "3" (configures three endpoints - "201",
"202" and "203)