Parameter Description
Note: For the parameter to take effect, a device reset is required.
Authentication per Port Table
Authentication
configure voip > gateway analog
authentication
[Authentication]
The table defines a user name and password for authenticating
each device port. The format of the ini file table parameter is as
follows:
[Authentication]
FORMAT Authentication_Index = Authentication_UserId,
Authentication_UserPassword, Authentication_Module,
Authentication_Port;
[\Authentication]
Where,
Module = Module number, where 1 denotes the module in Slot
1
Port = Port number, where 1 denotes the Port 1 of the module
For example:
Authentication 1 = lee,1552,1,2; (user name "lee" with password
1552 for authenticating Port 2 of Module 1)
For a description o this table, see Configuring Authentication on
page 633.
Note: The parameter is applicable only to analog interfaces.
Accounts Table
Accounts
configure voip > sip-definition
account
[Account]
Defines user accounts for registering and/or authenticating
(digest) Trunk Groups or IP Groups (e.g., an IP-PBX) with a
Serving IP Group (e.g., a registrar server).
The format of the ini file table parameter is as follows:
[Account]
FORMAT Account_Index = Account_ServedTrunkGroup,
Account_ServedIPGroupName, Account_ServingIPGroupName,
Account_Username, Account_Password, Account_HostName,
Account_ContactUser, Account_Register,
Account_RegistrarStickiness, Account_RegistrarSearchMode,
Account_RegEventPackageSubscription,
Account_ApplicationType;
[\Account]
For more information, see 'Configuring Registration Accounts' on
page 395.
Proxy Registration Parameters
Use Default Proxy
configure voip > sip-definition
settings > enable-proxy
[IsProxyUsed]
Enables the use of Proxy Set ID 0 (for backward compatibility).
[0] No = (Default) Proxy Set 0 is not used.
[1] Yes = Proxy Set ID 0 is used.
Note:
The parameter must be used only for backward compatibility.
If not required for backward compatibility, make sure that the
parameter is disabled and use the Proxy Sets table for
configuring all your Proxy Sets (except for Proxy Set ID 0).
If you are not using a proxy server, you must configure routing
rules to route the call.
The parameter is applicable only to the Gateway application.