EasyManua.ls Logo

AudioCodes Mediant 800B - Page 1145

AudioCodes Mediant 800B
1338 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version 7.2 1145 Mediant 800B Gateway & E-SBC
User's Manual 72. Configuration Parameters Reference
Parameter Description
received from the PBX. If this timer expires, the call is released. Note
that this is applicable only to the MFC-R2 CAS Brazil variant.
The valid range is 0 to 255 (in seconds). The default is 0.
Enable Reanswering Info
configure voip > gateway
advanced > reans-info-enbl
[EnableReansweringINFO]
For analog interfaces: Enables the device to send a SIP INFO
message with the On-Hook/Off-Hook parameter when the FXS phone
goes on-hook during an ongoing call and then off-hook again, within
the user-defined regret timeout (configured by the parameter
RegretTime). Therefore, the device notifies the far-
end that the call has
been re-answered.
For digital interfaces: The parameter is used for private wire services
(see Configuring Private Wiring Interworking on page 503).
[0] Disable (default)
[1] Enable
The parameter is typically implemented for incoming IP-to-Tel collect
calls to the FXS port. If the FXS user does not wish to accept the
collect call, the user disconnects the call by on-hooking the phone. The
device notifies the softswitch (or Application server) of the unanswered
collect call (on-hook) by sending a SIP INFO message. As a result, the
softswitch disconnects the call (sends a BYE message to the device).
If the call is a regular incoming call and the FXS user on-hooks the
phone without intending to disconnect the call, the softswitch does not
disconnect the call (during the regret time).
The INFO message format is as follows:
INFO sip:12345@10.50.228.164:5082 SIP/2.0
Via: SIP/2.0/UDP 127.0.0.1;branch=z9hG4bK_05_905924040-
90579
From:
<sip:+551137077803@ims.acme.com.br:5080;user=phone>;tag=00
8277765
To: <sip:notavailable@unknown.invalid>;tag=svw-0-1229428367
Call-ID: ConorCCR-0-LU-1229417827103300@dtas-
stdn.fs5000group0-000.l
CSeq: 1 INFO
Contact: sip:10.20.7.70:5060
Content-Type: application/On-Hook (application/Off-Hook)
Content-Length: 0
Note:
The parameter is applicable only if the parameter RegretTime is
configured.
The parameter is applicable only to FXS interfaces and E1/T1 CAS
interfaces.
PSTN Alert Timeout
configure voip > sip-
definition settings > pstn-
alert-timeout
[PSTNAlertTimeout]
Digital: Defines the Alert Timeout (in seconds) for calls sent to the
PSTN. This timer is used between the time a Setup message is sent to
the Tel side (IP-to-Tel call establishment) and a Connect message is
received. If an Alerting message is received, the timer is restarted. If
the timer expires before the call is answered, the device disconnects
the call and sends a SIP 40
8 request timeout response to the SIP party
that initiated the call.
Analog: Defines the Alert Timeout (in seconds) for calls to the Tel side.
This timer is used between the time a ring is generated (FXS) or a line
is seized (FXO), until the call is connected. For example: If the FXS