Parameter  Description 
[R1DetectionStandard]  Determines the MF-R1 protocol used for detection. 
  [0] = ITU (default) 
  [1] = R1.5 
Note: For the parameter to take effect, a device reset is required.
user-defined-tones-detector-
enable 
[UserDefinedToneDetectorEnable]
Enables the detection of User Defined Tones signaling, 
applicable for Special Information Tone (SIT) detection. 
  [0] = Disable (default) 
 
 = Enable 
sit-detector-enable 
[SITDetectorEnable] 
Enables SIT detection according to the ITU-T recommendation 
E.180/Q.35. 
  [0] = Disable (default) 
  [1] = Enable 
To disconnect IP-to-ISDN calls when a SIT tone is detected, the 
following parameters must be configured: 
  SITDetectorEnable = 1 
  UserDefinedToneDetectorEnable = 1 
  ISDNDisconnectOnBusyTone = 1 (applicable for Busy, 
Reorder and SIT tones) 
Another parameter for handling the SIT tone is SITQ850Cause, 
which determines the Q.850 cause value specified in the SIP 
Reason header that is included in a 4xx response when a SIT 
tone is detected on an IP-to-Tel call. 
To disconnect IP-to-CAS or IP-to-FXO calls when a SIT tone is 
detected, the following parameters must be configured: 
  SITDetectorEnable = 1 
  UserDefinedToneDetectorEnable = 1 
  DisconnectOnBusyTone = 1 (applicable fo
SIT tones) 
Note: 
  For the parameter to take effect, a device reset is required. 
  The IP-to-ISDN call is disconnected on detection of a SIT 
tone only in call alert state. If the call is in connected state, the 
SIT does not disconnect the call. Detection of busy or reorder 
tones disconnect these calls also in call connected state. 
  For IP-to-CAS calls, detection of busy, reorder, or SIT tones 
disconnect the call in any call state. 
udt-detector-frequency-deviation 
[UDTDetectorFrequencyDeviation]
Defines the deviation (in Hz) allowed for the detection of each 
signal frequency. 
The valid range is 1 to 50. The default is 50. 
Note: For the parameter to take effect, a device reset is required.
cpt-detector-frequency-deviation 
[CPTDetectorFrequencyDeviation] 
Defines the deviation (in Hz) allowed for the detection of each 
CPT signal frequency.  
The valid range is 1 to 30. The default is 10. 