Version 7.2  141  Mediant 800B Gateway & E-SBC 
 
User's Manual   12. Network 
The port names (strings) displayed in the Ethernet Groups table represent the physical 
ports on the device. For the mapping of these strings to the physical ports, see Configuring 
Physical Ethernet Ports on page 138. 
The following procedure describes how to configure Ethernet Groups through the Web 
interface. You can also configure it through ini file (EtherGroupTable) or CLI (configure 
network > ether-group). 
 
 
Note: 
•  If you want to assign a port to a different Ethernet Group, you must first remove 
the port from its current Ethernet Group. To remove the port, configure the 
'Member' field so that no port is selected or select a different port. 
•  As all ports have the same MAC address, you must connect each port to a 
different Layer-2 switch. 
•  When implementing 1+1 Ethernet port redundancy, each port in the Ethernet 
Group (port pair) must be connected to a different switch (but in the same subnet). 
 
  To configure Ethernet Groups: 
1.  Open the Ethernet Groups table (Setup  menu > IP Network  tab > Core Entities 
folder > Ethernet Groups). 
2.  Select the Ethernet Group that you want to configure, and then click Edit; the following 
dialog box appears: 
 
3.  Configure the Ethernet Group according to the parameters described in the table 
below.  
4.  Click Apply, and then save your settings to flash memory. 
Table  12-3: Ethernet Groups Table Parameter Descriptions 
Parameter  Description 
Index  (Read-only) Displays the index number for the table row. 
Name 
group 
[EtherGroupTable_Group] 
(Read-only) Displays the Ethernet Group number.