Version 7.2 301 Mediant 800B Gateway & E-SBC
User's Manual 15. Services
 To configure an HTTP Interface:
1. Open the HTTP Interfaces table (Setup menu > IP Network tab > HTTP Proxy folder >
HTTP Interfaces).
2. Click New; the following dialog box appears:
Figure 15-52: HTTP Interfaces Table - Add Dialog Box
3. Configure an HTTP Interface according to the parameters described in the table below.
4. Click Apply, and then save your settings to flash memory.
Table 15-21: HTTP Interfaces Table Parameter Descriptions
Parameter Description
General
Index
[HTTPInterface_Index]
Defines an index number for the new table row.
Note:
ï‚§ Each row must be configured with a unique index.
ï‚§ The parameter is mandatory.
Name
interface-name
[HTTPInterface_InterfaceName]
Defines a descriptive name, which is used when associating the row in
other tables.
The valid value is a string of up to 40 characters. By default, no value is
defined.
Note:
ï‚§ Each row must be configured with a unique name.
ï‚§ The parameter is mandatory.
Network Interface
network-interface
[HTTPInterface_NetworkInterface]
Assigns a local, network interface to the HTTP interface.
By default, no value is defined.
To configure network interfaces, see 'Configuring IP Network Interfaces'
on page 146.
Note: The parameter is mandatory.
Protocol
protocol
[HTTPInterface_Protocol]
Defines the protocol type.
ï‚§ [0] HTTP (default)
ï‚§ [1] HTTPS
HTTP Port
http-port
[HTTPInterface_Port]
Defines the local, listening HTTP port.
The valid value is 0 to 65534. The default is 0.
Note: The parameter is mandatory.