3.  Access the Web interface: 
a.  On your computer, start a Web browser and in the URL address field, enter the 
default IP address of the device; the Web interface's Web Login screen appears: 
Figure  4-1: Web Login Screen 
 
b.  In the 'Username' and 'Password' fields, enter the case-sensitive, default login 
username ("Admin") and password ("Admin"). 
c.  Click Login. 
4.  Configure the Ethernet port(s) that you want to use for the OAMP interface: 
a.  In the Ethernet Groups table, configure an Ethernet Group by assigning it up to 
two ports (two ports provide optional, port-pair redundancy). For more 
information, see Configuring Physical Ethernet Ports on page 138.   
b.  In the Physical Ports table, configure port settings such as speed and duplex 
mode (see Configuring Physical Ethernet Ports on page 138). 
c.  In the Ethernet Devices table, configure an Ethernet Device by assigning it the 
Ethernet Group and a VLAN ID (see 'Configuring Underlying Ethernet Devices' on 
page 142). 
5.  Modify the OAMP interface address to suite your network environment: 
a.  Open the IP Interfaces table (see 'Configuring IP Network Interfaces' on page 
146). 
 
b.  Select the OAMP interface ("O+M+C"), and then click Edit. 
c.  From the 'Ethernet Device' drop-down list, select the Ethernet Device that you 
configured in the previous step. 
d.   Under the IP Address group, change the IP address to correspond with your 
network IP addressing scheme.  
e.  Under the DNS group, configure the DNS server, if required. 
f.  Click Apply. 
6.  Save your settings by resetting the device with a flash burn (see 'Resetting the Device' 
on page 821). 
7.  Disconnect the device from your PC and re-cable it to your network. You can now 
access the device with the new OAMP interface address.