Version 7.2  471  Mediant 800B Gateway & E-SBC 
 
User's Manual   20. Coders and Profiles 
Parameter  Description 
  Dynamic Jitter Buffer Optimization Factor = 13 
  If the device initiates a fax session using G.711 (option 2 or 3), a 
'gpmd' attribute is added to the SDP in the following format: 
  For A-law: 'a=gpmd:8 vbd=yes;ecan=on' 
  For Mu-law: 'a=gpmd:0 vbd=yes;ecan=on' 
  When the parameter is set to 1, 2, or 3, the parameter 
FaxTransportMode is ignored. 
  When the parameter is set to 0, T.38 might still be used without the 
control protocol's involvement. To completely disable T.38, set 
FaxTransportMode to a value other than 1. 
  For more information on fax transport methods, see Fax/Modem 
Transport Modes on page 194.  
  The corresponding global parameter is IsFaxUsed. 
CNG Detector Mode 
cng-mode 
[IpProfile_CNGmode] 
Enables the detection of the fax calling tone (CNG) and defines the 
detection method.  
  [0] Disable = (Default) The originating fax does not detect CNG; the 
device passes the CNG signal transparently to the remote side.  
  [1] Relay = The originating fax detects CNG. The device sends 
CNG packets to the remote side according to T.38 (if IsFaxUsed is 
set to 1) and the fax session is started. A SIP Re-INVITE message 
is not sent and the fax session starts by the terminating fax. This 
option is useful, for example, when the originating fax is located 
behind a firewall that blocks incoming T.38 packets on ports that 
have not yet received T.38 packets from the internal network (i.e., 
originating fax). To also send a Re-INVITE message upon 
detection of a fax CNG tone in this mode, set the parameter 
FaxCNGMode to 1 or 2. 
  [2] Event Only = The originating fax detects CNG and a fax session 
is started by the originating fax, using the Re-INVITE message. 
Typically, T.38 fax session starts when the preamble signal is 
detected by the answering fax. Some SIP devices do not support 
the detection of this fax signal on the answering fax and thus, in 
these cases, it is possible to configure the device to start the T.38 
fax session when the CNG tone is detected by the originating fax. 
However, this mode is not recommended. 
Note: The corresponding global parameter is CNGDetectorMode. 
Vxx Modem Transport Type 
vxx-transport-type 
[IpProfile_VxxTransportType
] 
Defines the modem transport type. 
  [-1] = (Not Configured) The settings of the global parameters are 
used: 
  V21ModemTransportType 
  V22ModemTransportType 
  V23ModemTransportType 
  V32ModemTransportType 
  V34ModemTransportType 
  [0] Disable = Transparent. 
  [2] Enable Bypass (Default) 
  [3] Events Only = Transparent with Events. 
For a detailed description of the parameter per modem type, see the 
relevant global parameter (listed above). 
NSE Mode  Enables Cisco's compatible fax and modem bypass mode, Named