User's Manual  66  Document #: LTRT-10632 
 
  Mediant 800B Gateway & E-SBC 
For example, if you do not configure the 'SIP Interface' field (mandatory) for Proxy 
Set #0, the Invalid Line    icons are displayed for the Proxy Sets table, as 
shown below: 
Figure  6-11: Invalid Line (Row) Icons 
 
  Parameters that reference rows of other configuration tables that are configured 
with invalid values: If a row has a parameter that references a row of another table 
that has a parameter with an invalid value, the Invalid Reference Line   icon is 
displayed in the following locations: 
•  'Index' column of the row. 
•  Page title of the table. The total number of invalid rows in the table is also 
displayed with the icon. 
•  Item in the Navigation tree that opens the table. 
For example, if you configure IP Group #0 (in the IP Groups table) with a parameter 
that references Proxy Set #0, which is configured with an invalid value, Invalid 
Reference Line   icons are displayed for the IP Groups table, as shown below: 
Figure  6-12: Invalid Reference Line Icons 
 
  Invalid icon display in drop-down list items of parameters that can reference 
rows of other tables: 
•  If the row has an invalid line (see description above), the Invalid Line   icon 
appears along side the item. 
•  If the row has an invalid reference line (see description above), the Invalid 
Reference Line   icon appears along side it. 
For example, when configuring an IP Group, the 'Proxy Set' parameter's drop-down 
list displays items: Proxy Set #0 with   indicating that it has an invalid parameter 
value, and Proxy Set #1 with   indicating that it has a parameter that is referenced to 
a row of another table that has an invalid value: