EasyManua.ls Logo

AudioCodes Mediant 800B - Page 810

AudioCodes Mediant 800B
1338 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User's Manual 810 Document #: LTRT-10632
Mediant 800B Gateway & E-SBC
b. Open the IP Interfaces table (see 'Configuring IP Network Interfaces' on page
146).
c. Change the default OAMP network settings to suit your networking scheme.
d. Configure the Control and Media network interfaces, as required.
e. Add the HA Maintenance interface (i.e., the MAINTENANCE Application Type).
Note:
Make sure that the Maintenance interface uses an Ethernet Device and
Ethernet Group that is not used by any other IP network interface. The Ethernet
Group is associated with the Ethernet Device, which is assigned to the interface.
The IP Interfaces table below shows an example where the Maintenance interface is
configured with Ethernet Device "vlan 2" (which is associated with Ethernet Group
"GROUP_2"), while the other interface is assigned "vlan 1" (associated with Ethernet
Group "GROUP_1"):
Figure 42-4: Configuring MAINTENANCE Interface
3. If the connection is through a switch, the packets of both interfaces should generally
be untagged. To do this, open the Ethernet Devices table (see 'Configuring Underlying
Ethernet Devices' on page 142 ), and then configure the 'Tagging' parameter to
Untagged for the Ethernet Device assigned to the Maintenance interface. The figure
below shows an example (highlighted) where VLAN 2 is configured as the Native
(untagged) VLAN ID of the Ethernet Group "GROUP_2":
Figure 42-5: Configuring Untagged VLAN for Maintenance and Other Interfaces
4. Set the Ethernet port Tx / Rx mode of the Ethernet Group used by the Maintenance
interface (see 'Configuring Ethernet Port Groups' on page 140). The port mode
depends on the type of Maintenance connection between the devices, as described in
'Network Topology Types and Rx/Tx Ethernet Port Group Settings' on page 807.
5. Configure HA parameters:
a. Open the HA Settings page (Setup menu > IP Network tab > Core Entities
folder > HA Settings):
Figure 42-6: HA Settings Page

Table of Contents