User's Manual 920 Document #: LTRT-10632
Mediant 800B Gateway & E-SBC
Table 55-1: Description of Graphical Display of Device
Item # Description
1 Displays the highest severity of an active alarm raised (if any) by the device:
Green = No alarms
Red = Critical alarm
Orange = Major alarm
Yellow = Minor alarm
To view active alarms, click the Alarms area to open the Active Alarms page (see
Viewing Active Alarms on page 929).
2 Module slot number.
3 Module interface type (e.g., FXS, FXO, and DIGITAL).
4 Module status icon:
(green): Module has been inserted or is correctly configured
(gray): Module was removed and "Reserved" is displayed
(red): Module failure and "Failure" is displayed
5 Port (trunk or channel) status icon.
Icon Trunk Description
(Digital Module)
Channel Description
(Analog Modules)
(gray)
Disable: Trunk not
configured (not in use)
Idle: Channel is currently on-hook
(green)
Active - OK: Trunk
synchronized
Call Connected: Active RTP stream
(yellow)
RAI Alarm: Remote Alarm
Indication (RAI), also known
as the Yellow Alarm
-
(red)
LOS/LOF Alarm: Loss due to
LOS (Loss of Signal) or LOF
(Loss of Frame)
Not Connected: No FXO line is
connected to this port or port out of
service due to Serial Peripheral
Interface (SPI) failure (applicable
only to FXO interfaces)
(blue)
AIS Alarm: Alarm Indication
Signal (AIS), also known as
the Blue Alarm
Handset Offhook: Channel is off-
hook, but there is no active RTP
session
(orange)
D-Channel Alarm: D-channel
alarm
-
(dark orange)
NFAS Alarm -