User's Manual  968  Document #: LTRT-10632 
 
  Mediant 800B Gateway & E-SBC 
CDR Field  Description  CDR Report Type 
(SBCReportType) 
Format 
LegId 
Unique ID number of the call leg 
within a specific call session.  
A basic call consists of two legs 
(incoming leg and outgoing leg) and 
thus, two leg IDs are generated for 
the session, one for each leg. 
For each new call, the device 
assigns leg ID "1" to the first leg. 
The device then increments the leg 
ID for subsequent legs according to 
the leg sequence in the call session. 
For example, the device generates 
leg ID "1" for the incoming leg and 
leg ID "2" for the outgoing leg. If the 
call is transferred, the device 
generates leg ID "3" for the leg 
belonging to the call transfer target. 
Another example is a call forking 
session where the leg ID sequence 
may be as follows: incoming leg is 
"1", outgoing leg to user's office 
phone is "2" and outgoing leg to the 
user's mobile phone is "3". If the call 
is then transferred, the leg ID for the 
transfer leg is "4".  
"CALL_START",  
"CALL_CONNECT" 
and "CALL_END" 
String (decimal) 
Orig 
Call originator: 
  "LCL": local 
  "RMT": remote 
All  String 
SourceIp 
Source IP address  All  String (up to 20 
characters) 
SourcePort 
Source UDP port  All  String (up to 10 
characters) 
DestIp 
Destination IP address  All  String (up to 20 
characters) 
DestPort 
Destination UDP port  All  String (up to 10 
characters) 
TransportType 
Transport type: 
  "UDP" 
  "TCP" 
  "TLS" 
All  String 
SrcURI 
Source URI  All  String (up to 41 
characters) 
SrcURIBeforeMap 
Source URI before manipulation  All  String (up to 41 
characters) 
DstURI 
Destination URI  All  String (up to 41 
characters)