User's Manual 968 Document #: LTRT-10632
Mediant 800B Gateway & E-SBC
CDR Field Description CDR Report Type
(SBCReportType)
Format
LegId
Unique ID number of the call leg
within a specific call session.
A basic call consists of two legs
(incoming leg and outgoing leg) and
thus, two leg IDs are generated for
the session, one for each leg.
For each new call, the device
assigns leg ID "1" to the first leg.
The device then increments the leg
ID for subsequent legs according to
the leg sequence in the call session.
For example, the device generates
leg ID "1" for the incoming leg and
leg ID "2" for the outgoing leg. If the
call is transferred, the device
generates leg ID "3" for the leg
belonging to the call transfer target.
Another example is a call forking
session where the leg ID sequence
may be as follows: incoming leg is
"1", outgoing leg to user's office
phone is "2" and outgoing leg to the
user's mobile phone is "3". If the call
is then transferred, the leg ID for the
transfer leg is "4".
"CALL_START",
"CALL_CONNECT"
and "CALL_END"
String (decimal)
Orig
Call originator:
"LCL": local
"RMT": remote
All String
SourceIp
Source IP address All String (up to 20
characters)
SourcePort
Source UDP port All String (up to 10
characters)
DestIp
Destination IP address All String (up to 20
characters)
DestPort
Destination UDP port All String (up to 10
characters)
TransportType
Transport type:
"UDP"
"TCP"
"TLS"
All String
SrcURI
Source URI All String (up to 41
characters)
SrcURIBeforeMap
Source URI before manipulation All String (up to 41
characters)
DstURI
Destination URI All String (up to 41
characters)