EasyManua.ls Logo

AudioCodes Mediant 800B - Page 987

AudioCodes Mediant 800B
1338 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version 7.2 987 Mediant 800B Gateway & E-SBC
User's Manual 63. Reporting Information to External Party
2. Click New; the following dialog box appears:
Figure 63-6: Gateway CDR Format Table - Add Dialog Box
3. Configure CDR format rules according to the parameters described in the table below.
4. Click Apply.
An example of CDR customization rules configured in the table is shown below:
Figure 63-7: Examples of Configured Gateway CDR Customization Rules
Index 0: The default CDR field "Call Orig" for Syslog is changed to "Caller".
Index 1: The default CDR field "Destination IP" for Syslog is changed to "Destination
IP Address" (enclosed by apostrophes).
Index 2: The default CDR field "Setup Time" for Syslog is changed to "setup-time=".
Index 2: The default CDR field "Call Duration" for local CDR storage is changed to
"call-duration=".
Table 63-7: Gateway CDR Format Table Parameter Descriptions
Parameter Description
Index
[GWCDRFormat_Index]
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
CDR Type
cdr-type
[GWCDRFormat_CDRType]
Defines the application type for which you want to customize CDRs.
[0] Syslog Gateway = (Default) Customizes CDR field names for
CDRs (media and signaling) sent in Syslog messages.
[6] RADIUS Gateway = Customizes CDR field names (RADIUS
Attribute prefix names) for CDRs (media and signaling) sent in
RADIUS accounting requests.
[9] Local Storage Gateway = Customizes CDR fields (media and
signaling) that are stored locally on the device.

Table of Contents