Version 7.2 997 Mediant 800B Gateway & E-SBC
User's Manual 63. Reporting Information to External Party
For a detailed description of each parameter, see 'Syslog, CDR and Debug
Parameters' on page 1085.
3. Open the Logging Filters table (see 'Configuring Log Filter Rules' on page 1007), and
then configure a log filtering rule with the following settings:
'Filter Type' and 'Value': (as desired)
'Log Destination': Local Storage
'Log Type': CDR Only
'Mode': Enable
Note:
If you have enabled the CDR storage feature and you later decide to change the
maximum number of files (CDRLocalMaxNomOfFiles) to a lower value (e.g., from
50 to 10), the device stores the remaining files (e.g., 40) in its memory (i.e.,
unused files).
When the device operates in High-Availability mode, stored CDRs are deleted
upon device switchover.
For customizing CDR fields for SBC calls, see Customizing CDRs for SBC Calls
on page 990.
For customizing CDR fields for Gateway calls, see Customizing CDRs for
Gateway Calls on page 986.