Standard
RLL Instructions
5–13
Standard RLL Instructions
Boolean Instructions
The Out instruction reflects the status of
the rung (on/off) and outputs the discrete
(on/off) state to the specified image
register point or memory location.
Aaaa
OUT
Multiple Out instructions referencing the same discrete location should not be used
since only the last Out instruction in the program will control the physical output
point. Instead, use the next instruction, the Or Out.
Operand Data Type DL05 Range
A aaa
Inputs X 0–377
Outputs Y 0–377
Control Relays C 0–777
In the following Out example, when input X1 is on, output Y2 and Y5 will energize.
STR
$
1
B
ENT
OUT
GX
2
C
ENT
OUT
GX
ENT
5
F
Y2
OUT
X1
Y5
OUT
Handheld Programmer KeystrokesDirectSOFT
The Or Out instruction allows more than
one rung of discrete logic to control a
single output. Multiple Or Out
instructions referencing the same output
coil may be used, since all contacts
controlling the output are logically ORed
together. If the status of any rung is on,
the output will also be on.
A aaa
OR OUT
Operand Data Type DL05 Range
A aaa
Inputs X 0–177
Outputs Y 0–177
Control Relays C 0–777
In the following example, when X1 or X4 is on, Y2 will energize.
STR
$
1
B
ENT
STR
$
ENT
4
E
Y2
OR OUT
X1
Y2
OR OUT
X4
Handheld Programmer KeystrokesDirectSOFT
INST#
O
5
F
3
D
ENT ENT
2
C
ENT
2
C
ENT
INST#
O
5
F
3
D
ENT ENT
Out
(OUT)
Or Out
(OR OUT)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Automationdirect.com DL05 and is the answer not in the manual?

Automationdirect.com DL05 Specifications

General IconGeneral
BrandAutomationdirect.com
ModelDL05
CategoryController
LanguageEnglish

Related product manuals