Enters the default zone configuration submode.
Step 3 switch(config-default-zone)# attribute read-only
Sets read-only attributes for the default zone.
Step 4 (Optional) switch(config-default-zone)# no attribute read-only
Reverts the default zone attributes to read-write (default).
Configuring Read-Only Zones Using Fabric Manager
To configure read-only zones using Fabric Manager, follow these steps:
Step 1 Choose Zone > Edit Local Full Zone Database.
You see the Select VSAN dialog box.
Step 2 Select a VSAN and click OK.
You see the Edit Local Full Zone Database dialog box for the selected VSAN.
Step 3 Click Zones in the left pane and click the Insert icon to add a zone.
You see the Create Zone Dialog Box.
Figure 44: Create Zone Dialog Box
Step 4 Check the Read Only check box to create a read-only zone.
Step 5 Click OK.
To configure the read-only option for a default zone, see Configuring the Default Zone Policy, on page 92 section.
Displaying Zone Information
You can view any zone information by using the show command. If you request information for a specific
object (for example, a specific zone, zoneset, VSAN, or alias, or keywords such as brief or active), only
information for the specified object is displayed. If you do not request specific information, all available
information is displayed.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 8.x
104
Configuring and Managing Zones
Configuring Read-Only Zones Using Fabric Manager

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans
Power Supply OptionsAC and DC options available

Related product manuals