Configuring XRC Acceleration
IBM z/OS Global Mirror eXtended Remote Copy (XRC) is supported on the MSM-18+4 modules. For XRC
to function, XRC acceleration must be enabled on the FCIP tunnel interfaces on both ends. XRC acceleration
is disabled by default.
To enable XRC acceleration, follow these steps:
Step 1 switch# config t
switch(config)#
Enters the configuration mode.
Step 2 switch(config)# interface fcip 2
switch(config)#
Specifies an FCIP tunnel interface and enters interface configuration submode.
Step 3 switch(config-if)# ficon-xrc-emulator
switch(config)#
Enables XRC acceleration over the FCIP interface.
Step 4 switch(config-if)# no ficon-xrc-emulator
switch(config)#
Disables (default) XRC acceleration over the FCIP tunnel interface.
XRC acceleration and FICON tape acceleration cannot be enabled on the same FCIP tunnel interface and cannot
exist in the same VSAN.
Note
Moving a FICON VSAN to an Offline State
Issue the ficon vsan vsan-id offline command in EXEC mode to log out all ports in the VSAN that need to
be suspended.
Issue the EXEC-level ficon vsan vsan-id online command in EXEC mode to remove the offline condition
and to allow ports to log on again.
This command can be issued by the host if the host is allowed to do so (see the Allowing the Host to Move
the Switch Offline, on page 265).
Note
Cisco MDS 9000 Series Fabric Configuration Guide, Release 8.x
288
Configuring FICON
Configuring XRC Acceleration

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans
Power Supply OptionsAC and DC options available

Related product manuals