Step 3 switch(config-vsan-db)# vsan 2
Creates a VSAN with the specified ID (2) if that VSAN does not exist already.
Step 4 switch(config-vsan-db)# vsan 2 interface fc1/8
Assigns the membership of the fc1/8 interface to the specified VSAN (VSAN 2).
Step 5 switch(config-vsan-db)# vsan 7
Creates another VSAN with the specified ID (7) if that VSAN does not exist already.
Step 6 switch(config-vsan-db)# vsan 7 interface fc1/8
Updates the membership information of the interface to reflect the changed VSAN.
Step 7 switch(config-vsan-db)# vsan 1 interface fc1/8
Removes the interface fc1/8 from VSAN 7 to VSAN 1( the default VSAN).
To remove the VSAN membership of interface fc1/8 from VSAN 7, you should define the VSAN membership of fc1/8
to another VSAN.
The best practice is to assign it back to VSAN 1.
Displaying VSAN Static Membership
To display the VSAN static membership information, use the show vsan membership command (see Displays
Membership Information for the Specified VSAN, on page 14 through Displays Static Membership Information
for a Specified Interface, on page 15).
Displays Membership Information for the Specified VSAN
switch # show vsan 1 membership
vsan 1 interfaces:
fc1/1 fc1/2 fc1/3 fc1/4 fc1/5 fc1/6 fc1/7 fc1/9
fc1/10 fc1/11 fc1/12 fc1/13 fc1/14 fc1/15 fc1/16 port-channel 99
Interface information is not displayed if interfaces are not configured on this VSAN.
Note
Displays Static Membership Information for All VSANs
switch # show vsan membership
vsan 1 interfaces:
fc2/16 fc2/15 fc2/14 fc2/13 fc2/12 fc2/11 fc2/10 fc2/9
fc2/8 fc2/7 fc2/6 fc2/5 fc2/4 fc2/3 fc2/2 fc2/1
fc1/16 fc1/15 fc1/14 fc1/13 fc1/12 fc1/11 fc1/10 fc1/9
fc1/7 fc1/6 fc1/5 fc1/4 fc1/3 fc1/2 fc1/1
vsan 2 interfaces:
fc1/8
Cisco MDS 9000 Series Fabric Configuration Guide, Release 8.x
14
Configuring and Managing VSANs
Displaying VSAN Static Membership