member zone1
Referring back to the three entities of configuration, they are as follows on zone 1 before the zone merge:
• Saved configuration: nothing since zone information has not been saved by issuing the copy run start
command.
• Running configuration: consists of zone 1.
• Configured and learned information: consists of zone 1.
After the zone merge, the entities are:
• Saved configuration: nothing has been saved.
• Running configuration: consists of zone 1.
• Configured and learned information: consists of zone 1 and zone 2.
Zone 2 has not become part of the running configuration. Zone 2 has been learned, and is in the active zoneset.
Only when the zone copy active-zoneset full-zoneset vsan 100 command is issued, zone 2 becomes copied
from being learned to added to the running configuration. The configuration looks as follows after the command
is issued:
The zone copy command will delete all fcalias configuration.
Note
• Saved configuration: nothing has been saved.
• Running configuration: consists of zone 1 and zone 2.
• Configured and learned information: consists of zone 1 and zone 2.
Commands
By default zone in basic mode will only distribute active zoneset database only, this command was introduced
in 1.0.4 SAN-OS will propagate active zoneset and full zoneset database:
zoneset distribute full vsan vsan_id
If the zone update or zoneset activation is going on, the above command must be explicitly enabled on each
VSAN on every switch.
Enhanced mode: When zones are in enhanced mode, refer to the sample command outputs below.
1. Create zones and zoneset. Activate on Switch1.
Switch1# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch1(config)# vsan database
Switch1(config-vsan-db)# vsan 200
Switch1(config-vsan-db)# zone mode enhanced vsan 200
WARNING: This command would distribute the zoning database of this switch throughout the
fabric. Do you want to continue? (y/n) [n] y
Set zoning mode command initiated.
Check zone status
Switch1(config-vsan-db)# zone name zone1 vsan 200
Enhanced zone session has been created. Please 'commit' the changes when done.
Cisco MDS 9000 Series Fabric Configuration Guide, Release 8.x
124
Configuring and Managing Zones
Merge Process

Table of Contents

Other manuals for Cisco MDS 9000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco MDS 9000 Series and is the answer not in the manual?

Cisco MDS 9000 Series Specifications

General IconGeneral
CategorySwitch
Operating SystemCisco NX-OS
PortsVaries by model
ProtocolsFibre Channel (FC), Fibre Channel over IP (FCIP), iSCSI
RedundancyRedundant supervisors, power supplies, and fans
ManagementCisco Data Center Network Manager (DCNM), CLI, SNMP
Virtualization SupportVSANs (Virtual SANs)
Security FeaturesFibre Channel Security Protocol (FC-SP)
Hot Swappable Componentspower supplies, fans
Power Supply OptionsAC and DC options available

Related product manuals