A53 Z0 9 0020 L En Technical documentation
10.8 FUEL FILLING/ COOLANT FILLING/ OIL FILLING ....................................................................................................... 89
10.9 ANALOGUE LOAD SHARING LINE ........................................................................................................................ 91
10.10 WATCHDOG OUTPUT ................................................................................................................................. 92
11 I/O LINES .......................................................................................................................................................... 93
11.1 DIGITAL INPUT .............................................................................................................................................. 93
11.2 DIGITAL OUTPUTS .......................................................................................................................................... 97
11.3 ANALOGUE INPUT (VIA CRE CONFIG SOFTWARE) ................................................................................................. 101
12 PROTECTIONS ................................................................................................................................................. 106
12.1 DISABLE .................................................................................................................................................... 106
12.2 GENERATOR ELECTRICAL FAULT ....................................................................................................................... 106
12.3 MAINS ELECTRICAL FAULT .............................................................................................................................. 106
12.4 ALARM ..................................................................................................................................................... 106
12.5 FAULT (SOFT SHUT DOWN) ............................................................................................................................ 106
12.6 SECURITY (HARD SHUTDOWN)........................................................................................................................ 106
12.7 DROOP ..................................................................................................................................................... 106
12.8 HELP + FAULT (SOFT SHUT DOWN) .................................................................................................................. 106
12.9 HELP + GEN. ELECTRICAL FAULT ...................................................................................................................... 107
12.10 POTENTIAL ALARMS/FAULTS LIST ................................................................................................................ 107
13 ADDITIONAL FUNCTIONS ................................................................................................................................ 111
13.1 LOAD SHARING USING INTEGRAL (DE-DROOPING)................................................................................................. 111
13.2 OPERATOR CONTROLLED RETURN TO MAINS ....................................................................................................... 113
13.3 MAINS ELECTRICAL FAULT .............................................................................................................................. 113
13.4 GENERATOR ELECTRICAL FAULT ....................................................................................................................... 115
13.5 GENSYS 2.0 WITH EXTERNAL AUTOMATIC START MODULE .................................................................................... 116
13.6 REMOTE START UPON EXTERNAL PULSE ............................................................................................................. 118
13.7 SAFETY INHIBITIONS ..................................................................................................................................... 119
13.8 USE OF BSM II WITH GENSYS 2.0 ................................................................................................................. 121
13.9 GENSYS 2.0 WITH TEM COMPACT ................................................................................................................. 124
13.10 G59 NORM (ACCESS LEVEL -1) ................................................................................................................... 125
13.11 SCADA .................................................................................................................................................. 125
13.12 HOW TO SET A GPID ............................................................................................................................... 126
13.13 AUTOMATIC LOAD / UNLOAD ..................................................................................................................... 127
13.14 HEAVY CONSUMER (MARINE SEQUENCE) ....................................................................................................... 131
13.15 NON-ESSENTIAL CONSUMER TRIP (MARINE SEQUENCE) ..................................................................................... 133
13.16 PHASE OFFSET (DYN11 AND OTHER) ............................................................................................................ 136
13.17 VOLTAGE SYSTEM (120° THREE PHASES, 180° TWO PHASES, SINGLE PHASE) .......................................................... 137
13.18 MAINTENANCE CYCLE ............................................................................................................................... 138
13.19 FRONT PANEL INHIBITION .......................................................................................................................... 139
14 TEXT FILE & PLC .............................................................................................................................................. 140
14.1 INTRODUCTION ........................................................................................................................................... 140
14.2 VARIABLE NAMING ...................................................................................................................................... 140
14.3 TEXT FILE DESCRIPTION ................................................................................................................................. 141
14.4 PLC PROGRAMMING LANGUAGE ..................................................................................................................... 147
14.5 VARIABLES ................................................................................................................................................. 149
14.6 SYNTAX EXAMPLES ....................................................................................................................................... 150
14.7 GENSYS 1.0 – GENSYS 2.0 COMPATIBILITY .................................................................................................... 152
14.8 RESETTING TO FACTORY PARAMETERS ............................................................................................................... 154
14.9 DONWLOAD A CUSTOM LANGUAGE FILE ......................................................................................................... 154
15 COMMUNICATION ......................................................................................................................................... 155
15.1 CAN BUS GOOD PRACTICES ............................................................................................................................ 155
15.2 COM1: CRE TECHNOLOGY INTER-MODULES CAN BUS ........................................................................................ 157
15.3 COM2: CAN PROTOCOLS (CANOPEN, J1939, MTU MDEC): ............................................................................. 164
15.4 COM3: USB ............................................................................................................................................. 182
15.5 COM4: ETHERNET ................................................................................................................................... 182