EasyManua.ls Logo

CRE Technology GENSYS 2.0 - Page 81

CRE Technology GENSYS 2.0
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A53 Z0 9 0020 L En Technical documentation
Chapter : Dedicated I/O lines
81
See table below for preset settings. For specific setting contact your dealer.
Manufacturer
Model
AVR gain
[E1103]
AVR offset
[E1104]
Termi
nal H2
Termi
nal H4
Comment
STAMFORD
MX341
255
0
A2 (+)
A1 (-)
Trim pot of AVR fully CW
MX321
255
0
A2 (+)
A1 (-)
Trim pot of AVR fully CW
SX440
155
0
A2 (+)
A1 (-)
Trim pot of AVR fully CW
BASLER
AEC63-7
AVC63-4
AVC63-4A
APR63-5
APR125-5
SSR63-12
240
240
6
7
Remove the shunt
DECS32-
15-xxx
DECS63-
15-xxx
DECS125-
15-xxx
DECS300
-
-
-
-
Use VAR control included
in the DECS.
VR63-4
240
240
VAR+
VAR-
Remove the shunt
MARATHON
ELECTRIC
DVR2010
100
0
Aux
input
A
Aux
input
B
DVR2000
-
-
-
-
Replace with SE350 or
DVR2000E
AVK
Cosimat
N+
255
0
Pot +
Pot -
MA329
155
0
A2(+)
A1(-)
MarelliMotori
M8B
240
240
P
Q
Remove the shunt PQ
M8B400
0
0
8
6
470nF capacitor between
8 and M.
Don’t connect shield.
M405A640
0
0
6
8
470nF capacitor between
6 and M.
Don’t connect shield.
KATO
K65-12B
K125-10B
255
0
2
Or 4
3
Or 7
Jumpers have to be
removed.
MECC ALTE
SPA
UVR6
250
200
Pot +
Pot -
50kΩ in serial with H2
LEROY SOMER
R450
150
230
Pot
input
+
Pot
input -
Add shunt to select 50Hz
Remove LAM
R449
253
255
Pot
input
+
Pot
input -
Remove the shunt
R448
253
255
Pot
input
+
Pot
input -
Remove the shunt
R221
100
241
Pot
input
+(6)
Pot
input
(7)
Remove the shunt. Pot
ineffective

Table of Contents