195
M4.3-1055-063
04 Rev. 10/09
ELECTRICAL
ACCESS 123...System
P8 Raise Ramp = __; Adjusts how reactive the raise
function is to the inputs received from the multi-task
handle. Press the right arrow, which gives you access
to the two options shown below. Use the up/down ar-
rows to select either accel or decel. Accel stands for
acceleration - how quickly raise reacts when giving the
raise command. Decel stands for deceleration - how
quickly raise reacts when stopping the raise command.
Factory setting is 9 for P8.1 (Raise Accel) and 7 for
P8.2 (Raise Decel).
Press the right arrow and use the up/down arrows to
select desired setting. Range is 1 for the least reactive
to 9 for the most reactive. Press the enter/return button
to accept input. The menu will return to P8. Press the
down arrow to continue.
P9 Lower Ramp = __; Adjusts how reactive the lower
function is to the inputs received from the multi-task
handle. Press the right arrow, which gives you access
to the two options shown below. Use the up/down ar-
rows to select either accel or decel. Accel stands for
acceleration - how quickly lower reacts when giving the
lower command. Decel stands for deceleration - how
quickly lower reacts when stopping the lower com-
mand. Factory setting is 7 for P9.1 (Lower Accel) and
9 for P9.2 (Lower Decel).
Press the right arrow and use the up/down arrows to
select desired setting. Range is 1 for the least reactive
to 9 for the most reactive. Press the enter/return button
to accept input. The menu will return to P9. Press the
down arrow to continue.
P10 Tilt Ramp = __; Adjusts how reactive the tilt func-
tion is to the inputs received from the TBS/TDS. Press
the right arrow, which gives you access to two options,
accel or decel.
Use the up/down arrows to select either accel or decel.
Accel stands for acceleration - how quickly tilt reacts
when giving the tilt command. Decel stands for decel-
eration - how quickly tilt reacts when stopping the tilt
command. Factory setting is 6 for P10.1 (Accel) and 9
for P10.2 (Decel).
Press the right arrow and use the up/down arrows to
select desired setting. Range is 1 for the least reactive
to 9 for the most reactive. Press the enter/return button
to accept input. The menu will return to P10. Press the
down arrow to continue.
P11 Accy 1 Ramp = __; Adjusts how reactive the ac-
cessory 1 function is to the input received from the
multi-task handle. Press the right arrow, which gives
you access to two options, accel or decel.
Use the up/down arrows to select either accel or decel.
Accel stands for acceleration - how quickly the acces-
sory reacts when giving the accessory command. De-
cel stands for deceleration - how quickly the accessory
reacts when stopping the accessory command. Fac-
tory setting is 6 for P11.1 (Accel) and 9 for P11.2 (De-
cel).
Press the right arrow and use the up/down arrows to
select desired setting. Range is 1 for the least reactive
to 9 for the most reactive. Press the enter/return button
to accept input. The menu will return to P11 Accy 1
Ramp. Press the down arrow to continue.
Use the same procedures to adjust the next two set-
tings as just used for Accy Ramp 1. These settings ad-
just how reactive the accessory 2 and 3 function is to
the inputs received from the multi-task handle, and is
set up the same way.
P12 Accy 2 Ramp = __; Factory setting is 6 for P12.1
(Accel) and 9 for P12.2 (Decel).
P13 Accy 3 Ramp = __; Factory setting is 6 for P13.1
(Accel) and 9 for P13.2 (Decel).
When finished, press the down arrow to continue.
P14 Elevated Travel =___; Adjust the performance of
the following functions when the mast is above staging.
Press the right arrow to enter the following submenus
(F14.1, F14.2, F14.3, F14.4 and F14.5):
P14.1 Forward = ___mph; Maximum forward (forks
first) traction speed above free lift. Press the right arrow
and use the up/down arrows to select desired speed.
Range is 0 mph to 3.6 mph. Factory setting is 3.6 mph.
Press the enter/return button to accept input. The
menu will return to P14.1. Press the down arrow to con-
tinue.
P14.2 Reverse = ___ mph; Maximum reverse (power
unit first) traction speed above free lift. Press the right
arrow and use the up/down arrows to select desired
speed. Range is 0 mph to 3.9 mph. Factory setting is
3.9 mph. Press the enter/return button to accept input.
The menu will return to P14.2. Press the down arrow to
continue.
P14.3 Accel = ___; Acceleration rate (time for truck to
go from stop to top speed) above freelift. Press the
right arrow and use the up/down arrows to select de-
sired acceleration rate. Range is 1 for the longest ac-
celeration time to 9 for the shortest acceleration time.
Factory setting is 5. Press the enter/return button to ac-
cept. The menu will return to P14.3. Press the down
arrow to continue.