1084 | Virtual Link Trunking (VLT)
www.dell.com | support.dell.com
s4810-4#show running-config interface tengigabitethernet 0/40
!
interface TenGigabitEthernet 0/40
no ip address
!
port-channel-protocol LACP
port-channel 2 mode active
no shutdown
s4810-4#
configuring VLT peer lag in VLT
s4810-4#show running-config interface port-channel 2
!
interface Port-channel 2
no ip address
switchport
vlt-peer-lag port-channel 2
no shutdown
s4810-4#
s4810-4#show interfaces port-channel 2 brief
Codes: L - LACP Port-channel
LAG Mode Status Uptime Ports
L 2 L2L3 up 03:33:14 Te 0/40 (Up)
s4810-4#
In the ToR unit, configure LACP on the physical ports.
s60-1#show running-config interface tengigabitethernet 0/48
!
interface TenGigabitEthernet 0/48
no ip address
!
port-channel-protocol LACP
port-channel 100 mode active
no shutdown
s60-1#show running-config interface tengigabitethernet 0/50
!
interface TenGigabitEthernet 0/50
no ip address
!
port-channel-protocol LACP
port-channel 100 mode active
no shutdown
s60-1#
s60-1#show running-config interface port-channel 100
!
interface Port-channel 100
no ip address
switchport
no shutdown
s60-1#
s60-1#show interfaces port-channel 100 brief
Codes: L - LACP Port-channel
LAG Mode Status Uptime Ports
L 100 L2 up 03:33:48 Te 0/48 (Up)
Te 0/50 (Up)
s60-1#
Verify VLT is up. Verify that the VLTi (ICL) link, backup link connectivity (heartbeat status) and VLT
peer link (peer chassis) are all up: