Stacking | 979
Figure 47-6. Accessing Non-Master Units on a Stack via the Console Port
Stacking Cable Redundancy
You can connect two units with two or more stacking cables in case of a stacking port or cable failure.
Removal of only one of the cables does not trigger a reset.
Important Points to Remember - S4810 Stacking
For S4810 stacking using 40GE ports, any remaining 40 GE ports should not be configured as
quad-mode.
You may stack up to six S4810 systems
The S4810 cannot be stacked with other system types.
Stacking and Virtual Link Trunking (VLT)
cannot be enabled simultaneously on the S4810.
Data ports are configured as stacking ports in predefined groups of 4-10G ports called stack-groups.
When using the 40G ports, a single port can be configured as a stack port; each 40G port is a
stack-group.
All the ports in a stack-group are placed in stacking mode. Unused ports in that group cannot be used
as data ports.
The stack-group must contain only ports of the same type (all 10G or all 40G).
Stacking with 1G interfaces is
not supported.
Stacking on the S4810 is accomplished through front end user ports on the chassis
All stack units must have the same version of FTOS.
-------------------------------CONSOLE ACCESS ON THE STANDBY----------------------------------
2-unit-stack(standby)#?
cd Change current directory
clear Reset functions
copy Copy from one file to another
delete Delete a file
dir List files on a filesystem
disable Turn off privileged commands
enable Turn on privileged commands
exit Exit from the EXEC
format Format a filesystem
package automation package related commands
pwd Display current working directory
rename Rename a file
reset Reset selected card
show Show running system information
ssh-peer-stack-unit Open a SSH connection to the peer Stack-unit
start Start shell
telnet-peer-stack-unit Open a telnet connection to the peer Stack-unit
terminal Set terminal line parameters
upload Upload file
-------------------------------CONSOLE ACCESS ON A MEMBER-------------------------------------
Stack(stack-member-0)#?
reset-self Reset this unit alone
show Show running system information