EasyManua.ls Logo

Dell Force10 S4810P - Displaying Iscsi Optimization Information

Dell Force10 S4810P
1144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
iSCSI Optimization | 569
Displaying iSCSI Optimization Information
Use the show commands in Table 26-2 to display information on iSCSI optimization
Figure 26-2. show iscsi Command Example
9 (Optional) Enter interface configuration mode to
configure the auto-detection of Compellent disk
arrays.
interface port-type slot/port CONFIGURATION
10 (Optional) Configures the auto-detection of
Compellent arrays on a port.
Default: Compellent disk arrays are not detected.
[no] iscsi profile-compellent
INTERFACE
Table 26-2. Displaying iSCSI Optimization Information
Command Output
show iscsi (Figure 26-2) Displays the currently configured iSCSI settings.
show iscsi sessions (Figure 26-3) Displays information on active iSCSI sessions on the switch.
show iscsi sessions detailed [session isid]
(Figure 26-4)
Displays detailed information on active iSCSI sessions on the switch. To
display detailed information on specified iSCSi session, enter the session’s
iSCSi ID.
show run iscsi Displays all globally-configured non-default iSCSI settings in the current
FTOS session.
Step Task Command Command Mode
FTOS#show iscsi
iSCSI is enabled
iSCSI session monitoring is disabled
iSCSI COS : dot1p is 4 no-remark
Session aging time: 10
Maximum number of connections is 256
------------------------------------------------
iSCSI Targets and TCP Ports:
------------------------------------------------
TCP Port Target IP Address
3260
860

Table of Contents

Other manuals for Dell Force10 S4810P

Related product manuals