Stacking | 999
0 0 down DC down
0 1 up DC up
1 0 absent absent
1 1 up AC up
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
--------------------------------------------------------------------------------
0 0 up up 6960 up 6720
0 1 up up 6720 up 6720
1 0 up up 6960 up 6720
1 1 up up 6720 up 6720
Speed in RPM
stack-1#
Recover from a Card Mismatch State on an S-Series Stack
A card mismatch occurs if the stack has a provision for the lowest available stack number which does not
match the model of a newly added unit. See the following example. To recover, disconnect the new unit.
Then, either:
remove the provision from the stack, then reconnect the standalone unit, or
renumber the standalone unit with another available stack number on the stack.
Figure 47-14. Recovering from a Card Mismatch State on an S-Series Stack (S50N and S25N)
-----------------------------------STANDALONE UNIT BEFORE------------------------------------
Standalone#show system brief
Stack MAC : 00:01:e8:d5:ef:81
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
---------------------------------------------------------------------------
0 Management online S50V S50V 7.8.1.0 52
1 Member not present S50N
2 Member not present S50V
3 Member not present S50V
4 Member not present
5 Member not present
6 Member not present
7 Member not present
---------------------------------------STACK BEFORE------------------------------------------
Stack#show system brief
Stack MAC : 00:01:e8:d5:f9:6f
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
---------------------------------------------------------------------------
0 Member not present S25N
1 Management online S50N S50N 7.8.1.0 52
2 Standby online S50V S50V 7.8.1.0 52
3 Member not present
4 Member not present
5 Member not present
6 Member not present
7 Member not present
-----------------------------------STANDALONE UNIT AFTER------------------------------------
01:38:34: %STKUNIT0-M:CP %POLLMGR-2-ALT_STACK_UNIT_STATE: Alternate Stack-unit is present
01:38:34: %STKUNIT0-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 1 present
Going for reboot. Reason is Stack merge