EasyManua.ls Logo

Dell Force10 S4810P - Stacking LAG; Supported Stacking Topologies

Dell Force10 S4810P
1144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
976 | Stacking
www.dell.com | support.dell.com
Figure 47-3. Adding a Standalone with a Lower MAC Address and Equal Priority to a Stack—After
Stacking LAG
When multiple links are used between stack units, FTOS automatically bundles them in a stacking LAG to
provide aggregated throughput and redundancy. The stacking LAG is established automatically and
transparently by FTOS (without user configuration) once peering is detected and behaves as follows:
The stacking LAG dynamically aggregates; it can lose link members or gain new links.
Shortest path selection inside the stack: If multiple paths exist between two units in the stack, the
shortest path is used.
Supported Stacking Topologies
The S4810 supports stacking in a ring or a daisy chain topology. Dell Force10 recommends the ring
topology when stacking S4810 switches to provide redundant connectivity.
-------------------------------STANDALONE AFTER CONNECTION----------------------------------
Standalone#%STKUNIT0-M:CP %POLLMGR-2-ALT_STACK_UNIT_STATE: Alternate Stack-unit is present
00:20:20: %STKUNIT0-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 1 present
00:20:22: %STKUNIT0-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 2 present
Going for reboot. Reason is Stack merge
[bootup messages omitted]
------------------------------------STACK AFTER CONNECTION----------------------------------
Stack# 3w1d14h: %STKUNIT1-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 2 present
3w1d14h: %STKUNIT1-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 2 down - card removed
3w1d14h: %STKUNIT1-M:CP %CHMGR-5-STACKUNITDETECTED: Stack unit 2 present
3w1d14h: %STKUNIT1-M:CP %CHMGR-5-CHECKIN: Checkin from Stack unit 2 (type S50V, 52 ports)
3w1d14h: %S50V:2 %CHMGR-0-PS_UP: Power supply 0 in unit 2 is up
3w1d14h: %STKUNIT1-M:CP %CHMGR-5-STACKUNITUP: Stack unit 2 is up
Stack#show system brief
Stack MAC : 00:01:e8:d5:f9:6f
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
---------------------------------------------------------------------------
0 Standby online S50V S50V 7.8.1.0 52
1 Management online S50N S50N 7.8.1.0 52
2 Member online S50V S50V 7.8.1.0 52
3 Member not present
4 Member not present
5 Member not present
6 Member not present
7 Member not present