994 | Stacking
www.dell.com | support.dell.com
Display Status of Stacking Ports
To display the status of the stacking ports, including the topology:
The following example shows four switches stacked together with two 40G links in a ring topology.
FTOS#show system stack-ports
Topology: Ring
Interface Connection Link Speed Admin Link Trunk
(Gb/s) Status Status Group
------------------------------------------------------------------
1/48 7/56 40 up up
1/52 5/60 40 up up
2/56 6/52 40 up up
2/60 4/52 40 up up
3/48 7/52 40 up up
3/52 5/56 40 up up
4/52 6/48 40 up up
4/56 4/48 40 up up
FTOS#
The following example shows the parameters for the management unit in the stack.
FTOS#show system stack-unit 1
-- Unit 1 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S4810 - 52-port GE/TE/FG (SE)
Current Type : S4810 - 52-port GE/TE/FG (SE)
Master priority : 0
Hardware Rev : 3.0
Num Ports : 64
Up Time : 1 min, 14 sec
FTOS Version : 4810-8-3-12-1447
Jumbo Capable : yes
POE Capable : no
Boot Flash : 1.2.0.2
Memory Size : 2147483648 bytes
Temperature : 44C
Voltage : ok
Serial Number : H1DL104400018
Part Number : Rev
Vendor Id :
Date Code :
Country Code :
Piece Part ID : N/A
PPID Revision : N/A
Service Tag : N/A
Expr Svc Code : N/A
Auto Reboot : disabled
Burned In MAC : 00:01:e8:8c:53:32
No Of MACs : 3