952 | Simple Network Management Protocol (SNMP)
www.dell.com | support.dell.com
Table 46-1 lists the traps the RFC-defined SNMP traps and the command used to enable each. Note that
the coldStart and warmStart traps are enabled using a single command.
Enable a subset of Dell Force10 enterprise specific SNMP traps using one of the listed command options in
Table 46-2 with the command
snmp-server enable traps. Note that the envmon option enables all
environment traps including those that are enabled with the envmon supply, envmon temperature, and
envmon fan options.
2
Specify which traps the Dell Force10 system sends
to the trap receiver.
Enable all Dell Force10 enterpriseSpecific and
RFC-defined traps using the command
snmp-server enable traps from
CONFIGURATION mode.
Enable all of the RFC-defined traps using the
command
snmp-server enable traps snmp
from CONFIGURATION mode.
snmp-server enable traps
CONFIGURATION
3
Specify the interfaces out of which FTOS sends
SNMP traps.
snmp-server trap-source
CONFIGURATION
Table 46-1. RFC 1157 Defined SNMP Traps on FTOS
Command Option Trap
snmp authentication SNMP_AUTH_FAIL:SNMP Authentication failed.Request with invalid community string.
snmp coldstart SNMP_COLD_START: Agent Initialized - SNMP COLD_START.
SNMP_WARM_START: Agent Initialized - SNMP WARM_START.
snmp linkdown PORT_LINKDN:changed interface state to down:%d
snmp linkup PORT_LINKUP:changed interface state to up:%d
Table 46-2. Dell Force10 Enterprise-specific SNMP Traps
Command Option Trap
envmon CARD_SHUTDOWN: %sLine card %d down - %s
CARD_DOWN: %sLine card %d down - %s
LINECARDUP: %sLine card %d is up
CARD_MISMATCH: Mismatch: line card %d is type %s - type %s required.
RPM_STATE: RPM1 is in Active State
RPM_STATE: RPM0 is in Standby State
RPM_DOWN: RPM 0 down - hard reset
RPM_DOWN: RPM 0 down - card removed
HOT_FAILOVER: RPM Failover Completed
SFM_DISCOVERY: Found SFM 1
SFM_REMOVE: Removed SFM 1
MAJOR_SFM: Major alarm: Switch fabric down
MAJOR_SFM_CLR: Major alarm cleared: Switch fabric up
Step Task Command Command Mode