EasyManua.ls Logo

Dell Force10 S4810P - Page 987

Dell Force10 S4810P
1144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Stacking | 987
4 Member not present
5 Member not present
6 Member not present
7 Member not present
8 Member not present
9 Member not present
10 Member not present
11 Member not present
Figure 47-9. Adding an S4810 Stack Unit with a Conflicting Stack Number—After
FTOS#show system brief
Stack MAC : 00:01:e8:8a:df:e6
Reload Type : normal-reload
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
---------------------------------------------------------------------------
0 Management online S4810 S4810 8-3-7-13 64
1 Member online S4810 S4810 8-3-7-13 64
2 Member not present
3 Standby online S4810 S4810 8-3-7-13 64
4 Member not present
5 Member not present
6 Member not present
7 Member not present
8 Member not present
9 Member not present
10 Member not present
11 Member not present
Add a Configured Unit to an Existing Stack
To add a configured unit to an existing stack use the following steps.
If a stack unit goes down and is removed from the stack, the logical provisioning configured for that
stack-unit number is saved on the master and standby units. When a new unit is added to the stack, if a
stack group configuration conflict occurs between the new unit and the provisioned stack unit, the
configuration of the new unit takes precedence.
Step Task Command Syntax Command Mode
1 Add the configured unit to the top or bottom of the stack.
2 Power on the switch.
3 Attach cables to connect ports on the added switch to one or more existing switches in the stack.
4 Logon to the CLI and enter global configuration
mode.
Login: username
Password: *****
FTOS> enable
FTOS# configure

Table of Contents

Other manuals for Dell Force10 S4810P