TX1320 M1
Upgrade and Maintenance Manual 101
Basic software procedures
Ê Under Network Inventory, you will find detailed information on each network
controller in the managed PRIMERGY server, including its MAC address.
I This information is only available with the iRMC S4 or above.
Only network controllers supporting the Command Line Protocol
(CLP) will be displayed.
Ê Inform the customer about the changed MAC address.
5.2.15.2 Looking up WWN addresses
Emulex FC / FCoE adapters
Ê Enable the network controllers Option ROM in the system board BIOS as
described in section "Enabling Option ROM scan" on page 88.
Ê Restart the server.
Ê During boot, as soon as the Emulex BIOS utility option appears, press
[ALT]+[E] or [CTRL]+[E].
Ê Under Emulex Adapters in the System you will find all available Emulex
adapters and their WWN addresses.
Ê Note down the new 16-digit WWN address.
Ê Press [Esc] to exit the Emulex BIOS utility.
Ê Inform the customer about the changed WWN address.
QLogic FC adapters
Ê Enable the network controllers Option ROM in the system board BIOS as
described in section "Enabling Option ROM scan" on page 88.
Ê Restart the server.
Ê During boot, as soon as the QLogic BIOS utility option appears, press
[ALT]+[Q] or [CTRL]+[Q].
Ê Under Select Host Adapter use the arrow keys æ/Ë to select the desired
FC / FCoE adapter and press [Enter].
Ê From the Fast!UTIL Options menu, select Configuration Settings, and press
[Enter].
Ê From the Configuration Settings menu, select Adapter Settings, and press
[Enter].