EasyManua.ls Logo

Fujitsu PRIMERGY TX1320 M1

Fujitsu PRIMERGY TX1320 M1
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
94 Upgrade and Maintenance Manual
TX1320 M1
Basic software procedures
5.2.9 Verifying the memory mode
If a memory module fails, the server will reboot and the defective module will be
disabled. As a result, the current operation mode (e.g. Mirrored Channel mode)
may no longer be available due to a lack of identical memory module pairs. In
this case, the operation mode will automatically revert to Independent Channel
Mode.
I For detailed information on memory operation modes available for your
server, refer to section "Operation modes" on page 218.
After replacing the defective module(s) the memory operation mode is
automatically reset to its original state. It is recommended to verify that the
operation mode has been correctly.
Ê Enter the BIOS.
Ê Select the Advanced menu.
Ê Under Memory Status verify that none of the memory modules are marked as
Failed.
Ê Save your changes (if applicable) and exit the BIOS.
I For detailed information on how to access the BIOS and modify settings,
refer to the corresponding BIOS Setup Utility reference manual.

Table of Contents

Other manuals for Fujitsu PRIMERGY TX1320 M1

Related product manuals