EasyManua.ls Logo

Fujitsu PRIMERGY TX1320 M1

Fujitsu PRIMERGY TX1320 M1
340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TX1320 M1
Upgrade and Maintenance Manual 245
Accessible drives
12.2.2 Removing an optical disk drive (ODD)
12.2.2.1 Preliminary steps
Before installing an accessible drive, perform the following steps:
Ê Disable BitLocker functionality as described in section "Disabling BitLocker
functionality" on page 73.
Ê Remove optical disk media from the drive.
Ê Shut down the server as described in section "Shutting down the server" on
page 52.
Ê Disconnect the AC power cord from the system.
Ê Remove the server cover as described in section "Opening the server" on
page 55.
Field Replaceable Unit
(FRU)
Hardware: 10 minutes
Tools:
Preliminary and concluding steps: Slotted screw driver (only for
removing the optical disk drive filler cover)
Installing accessible drives: tool-less

Table of Contents

Other manuals for Fujitsu PRIMERGY TX1320 M1

Related product manuals