84 Upgrade and Maintenance Manual
TX1320 M1
Basic software procedures
Ê Disable BIOS recovery mode using the onboard jumpers:
I For detailed information on jumper settings, refer to section "Onboard
settings" on page 327 or the "System Board D3239 Technical
Manual".
Ê Close the side / top cover as described in section "Closing the server" on
page 64.
5.2.1.2 Updating or recovering the iRMC
iRMC flash procedure
I For the Japanese market, follow the instructions provided separately.
Ê Prepare a USB stick including the bootable iRMC firmware update image.
Ê Connect the USB stick to the USB port.
I Ensure that only the USB device with the iRMC firmware is connected
to the USB port. Remove all other USB devices temporarily.
Ê Restart the server.
Ê The system will detect the USB stick.
I If the BIOS cannot identify the USB stick, the pop-up message
Failed to boot for Emergency flash. Please Reset now.
will show up in the center of the screen.
Ê Choose one of the following options from the update tool menu to start the
iRMC update process:
Normal Choose this option to update an existing system board.
Initial Choose this option if the system board has been replaced prior to the
iRMC update procedure. This option will perform all relevant flash
procedures in a row, including the iRMC firmware and bootloader.
V CAUTION!
Do not interrupt the iRMC upgrade process after it has started. If the
process is interrupted, the iRMC BIOS may be permanently
corrupted.
I If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.

Table of Contents

Other manuals for Fujitsu PRIMERGY TX1320 M1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY TX1320 M1 and is the answer not in the manual?

Fujitsu PRIMERGY TX1320 M1 Specifications

General IconGeneral
Processor Sockets1
Memory Slots4
Form FactorTower
ProcessorIntel Celeron
StorageUp to 4 x 3.5" or 2.5" drives
Drive Bays4 x 3.5-inch or 8 x 2.5-inch
RAID SupportRAID 0, 1, 10
Network ControllerDual-port Gigabit Ethernet
Operating System SupportLinux

Related product manuals