7.3.3.3 Concluding steps
Perform the following procedures to complete the task:
Ê Close the front cage as described in section "Closing the front cage" on
page 62.
Ê Close the server cover as described in section "Mounting the server cover"
on page 66.
7.3.4 Replacing a 3.5-inch HDD module
V CAUTION!
●
Only remove an HDD module during operation if the drive is not
currently being accessed. Observe the indicators for the
corresponding HDD modules, see "FUJITSU Server PRIMERGY
TX1320 M1 Operating Manual".
●
Under no circumstances should you remove an HDD module while
the system is in operation if you are not sure that the drive is operated
by a RAID controller and belongs to a disk array that is operating in
RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD module can only be replaced during operation in conjunction
with a corresponding RAID configuration.
●
All HDD modules (drives) must be uniquely identified so that they can
be reinstalled in their original mounting locations later. If this is not
done, existing data can be lost.
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Tools: tool-less