12.3.1.5 Concluding steps
Perform the following procedures to complete the task:
Ê Close the front cage as described in "Closing the front cage" on page 62.
Ê Close the server cover as described in section "Closing the server" on
page 64.
Ê Reconnect the AC power cord to the power supply unit.
Ê If BitLocker functionality is used and has been disabled before starting the
maintenance task, re-enable BitLocker as described in section "Enabling
BitLocker functionality" on page 99.
Ê Verify if your backup software solution requires additional configuration after
installing, removing or replacing an accessible drive as described in section
"Verifying and configuring the backup software solution" on page 77.
12.3.2 Removing backup drive
12.3.2.1 Preliminary steps
Before installing an accessible drive, perform the following steps:
Ê Disable BitLocker functionality as described in section "Disabling BitLocker
functionality" on page 73.
Ê Remove any backup medium from the drive.
Ê Shut down the server as described in section "Shutting down the server" on
page 52.
Ê Disconnect the AC power cord from the system.
Ê Remove the server cover as described in section "Opening the server" on
page 55.
Field Replaceable Unit
(FRU)
Hardware: 10minutes
Tools:
Preliminary and concluding steps: tool-less
Removing accessible drives: Phillips PH2 / (+) No. 2 screw driver