MOD Functions | Setting up data interfaces
19
HEIDENHAIN | TNC 620 | Conversational Programming User's Manual | 10/2017
753
Set handshake
(flowControl no. 106706)
By handshaking, two devices control data transfer between them.
A distinction is made between software handshaking and hardware
handshaking.
No data flow checking (NONE): Handshaking is not active
Hardware handshaking (RTS_CTS): Transmission stop is active
through RTS
Software handshaking (XON_XOFF): Transmission stop is active
through DC3 (XOFF)
File system for file operation
(fileSystem no. 106707)
In fileSystem you define the file system for the serial interface.
This machine parameter is not required if you don't need a special
file system.
EXT: Minimum file system for printers or non-HEIDENHAIN
transmission software. It corresponds to the EXT1 and EXT2
operating modes on older HEIDENHAIN controls.
FE1: Communication with the TNCserver PC software or an
external floppy disk unit.
Block check character
(bccAvoidCtrlChar no. 106708)
With Block Check Character (optional) no control character, you
determine whether the checksum can correspond to a control
character.
TRUE: The checksum does not correspond to a control character
FALSE: The checksum can correspond to a control character
Condition of RTS line
(rtsLow no. 106709)
With the state of the RTS line (optional), you can define whether
the LOW level is active in idle state.
TRUE: Level is LOW in idle state
FALSE: Level is not LOW in idle state