Table 21 on page 104 provides the required environmental conditions for normal switch operation.
Table 21: EX Series Switch Environmental Tolerances
Environment Tolerance
Switch or
device SeismicTemperatureRelative HumidityAltitude
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured
in the temperature range
32° F (0° C) through 104°
F (40° C) at altitudes up to
5,000 ft (1,524 m).
For information about
extended temperature SFP
transceivers supported on
EX2200 switches, see
Pluggable Transceivers
Supported on EX2200
Switches.
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
No performance
degradation up to
5,000 feet (1524
meters)
EX2200-C
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured
in the temperature range
32° F (0° C) through 113°
F (45° C)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX2200
(except
EX2200-C
switches)
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured
in the temperature range
32° F (0° C) through 104°
F (40° C)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
No performance
degradation up to
5,000 feet
(1524 meters)
EX2300-C
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured
in the temperature range
32° F (0° C) through 113°
F (45° C)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
No performance
degradation up to
13,000 feet
(3962 meters) at
104° F (40° C) as
per GR-63
EX2300
(except
EX2300-C
switches)
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured
in the temperature range
32° F (0° C) through 113°
F (45° C)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX3200
104